Fuel Pressure Regulator
- Connect Fuel Pressure Gauge (999-5011 ) between fuel line and fuel rail. Seal free end of hose with Plug (999-5266 ). Start fuel pumps. Lift out central electrical unit and remove system relay. See Fig 1 .
- Connect a jumper wire between relay terminals No. 30 and 87/2. See Fig 2 . Remove fuses No. 30 and 31. See Fig 3 . Connect a jumper wire between right fuse terminals. See Fig 3 . Fuel pumps should start. Fuel filler cover can be removed to determine whether main pump is operating.