Signal Specification, Keyless Vehicle Module (KVM)
General
All values given below are between the terminals stated in column 1 and terminal #B4 (power ground). This applies unless otherwise indicated in brackets.
NOTE:
It is important to connect the breakout box and check the ground terminals before taking readings.
| U= | DC voltage in volts (V) | ||
| Ubat = | Battery voltage (V) | ||
| Ulow = | Voltage approximately 0 V |
Connector A
| Connector A | ||||
|---|---|---|---|---|
| Breakout box terminal | Control module terminal | Signal type | Active / Not active | Miscellaneous |
| #C1 | #A1 | Signal cable inner antenna in the passenger compartment (middle) (-) | f=125kHz U=300Vpp The signal is difficult to measure. |
Located under the carpet between the center console and the rear seat. Only active when searching for remote keys. Otherwise 0 V. |
| #C2 | #A2 | Signal cable inner antenna in the passenger compartment (front) (+) | f=125kHz U=300Vpp The signal is difficult to measure. |
Located under the carpet in front of the center panel. Only active when searching for keys. Otherwise 0 V. (-) for the C70. |
| #C3 | #A3 | Signal cable external left-hand antenna (+) | f=125kHz U=300Vpp The signal is difficult to measure. |
For the S40 and V50: Placed in the outer door handle in the left-hand rear door. For the C30 and C70: Placed in the outer door handle in the left-hand front door. (-) for C30 and C70. |
| #C4 | #A4 | Reserve | - | - |
| #C5 | #A5 | Reserve | - | - |
| #C6 | #A6 | Not connected | - | - |
| #C7 | #A7 | Not connected | - | - |
| #C8 | #A8 | Not connected | - | - |
| #C9 | #A9 | Not connected | - | - |
| #C10 | #A10 | Not connected | - | - |
| #C11 | #A11 | Not connected | - | - |
| #C12 | #A12 | Not connected | - | - |
| #C13 | #A13 | Not connected | - | - |
| #C14 | #A14 | The signal cable external right-hand antenna (-) | f=125kHz U=300Vpp The signal is difficult to read |
For the S40 and V50: Placed in the outer door handle in the right-hand rear door. For the C30 and C70: Placed in the outer door handle in the right-hand front door. (+) for C30 and C70. Only active when searching for remote keys. Otherwise 0 V. |
| #C15 | #A15 | Signal cable external left-hand antenna (-) | f=125kHz U=300Vpp The signal is difficult to measure. |
For the S40 and V50: Placed in the outer door handle in the left-hand rear door. For the C30: Placed in the outer door handle in the left-hand front door. (+) for C30 and C70. Only active when searching for remote keys. Otherwise 0 V. |
| #C16 | #A16 | Reserve | - | - |
| #C17 | #A17 | Signal cable inner antenna in the passenger compartment (middle) (+) | f=125kHz U=300Vpp The signal is difficult to measure. |
Located under the carpet between the center console and the rear seat. Only active when searching for remote keys. Otherwise 0 V. |
| #C18 | #A18 | Signal cable inner antenna passenger compartment (front) (-) | f=125kHz U=300Vpp The signal is difficult to measure. |
Located under the carpet in front of the center panel. Only active when searching for keys. Otherwise 0 V. (+) for C70. |
| #C19 | #A19 | Reserve | - | - |
| #C20 | #A20 | Reserve | - | - |
| #C21 | #A21 | Signal cable outer antenna rear (+) | f=125kHz U=300Vpp The signal is difficult to read |
Located in the rear bumper. Only active when searching for remote keys. Otherwise 0 V. (-) for the C30. |
| #C22 | #A22 | Signal cable to external antenna rear (-). | f=125kHz U=300Vpp The signal is difficult to measure. |
Located in the rear bumper. Only active when searching for remote keys. Otherwise 0 V. (+) for C30. |
| #C23 | #A23 | The signal cable external right-hand antenna (+) | f=125kHz U=300Vpp The signal is difficult to measure. |
For the S40 and V50: Placed in the outer door handle in the right-hand rear door. For the C30 and C70: Placed in the outer door handle in the right-hand front door. (-) for C30 and C70. Only active when searching for remote keys. Otherwise 0 V. |
Connector B
| Connector B | ||||
|---|---|---|---|---|
| Breakout box terminal | Control module terminal | Signal type | Active / Not active | Miscellaneous |
| #B24 | #B1 | Reserve | - | - |
| #B25 | #B2 | - supply for quick lock left rear (+) | > 10.5 V / < 1.5 V | Active for approximately 0.5 seconds when opening doors. Not C30 and C70. |
| #B26 | #B3 | Supply for quick lock right rear (+) | > 10.5 V / < 1.5 V | Active for approximately 0.5 seconds when opening doors. Not C30 and C70. |
| #B27 | #B4 | Supply for quick lock left front (+) | > 10.5 V / < 1.5 V | Active for approximately 0.5 seconds when opening doors. |
| #B28 | #B5 | Supply for quick lock right front (+) | > 10.5 V / < 1.5 V | Active for approximately 0.5 seconds when opening doors. |
| #B29 | #B6 | Not connected | - | - |
| #B30 | #B7 | Not connected | - | - |
| #B31 | #B8 | Not connected | - | - |
| #B32 | #B9 | Not connected | - | - |
| #B33 | #B10 | Not connected | - | - |
| #B34 | #B11 | Not connected | - | - |
| #B35 | #B12 | Not connected | - | - |
| #B36 | #B13 | Not connected | - | - |
| #B37 | #B14 | Signal cable inner antenna in the passenger compartment (rear) (+) | f=125kHz U=300Vpp The signal is difficult to measure. |
Located under the carpet in the cargo compartment. Only active when searching for remote keys. Otherwise 0 V. (-) for the S40. Spare on C30 |
| #B38 | #B15 | Signal cable inner antenna in the passenger compartment (rear) (-) | f=125kHz U=300Vpp The signal is difficult to measure. |
Only S40 and C70. Located under the carpet in the luggage compartment. Only active when searching for remote keys. Otherwise 0 V. (+) for the S40. |
| #B39 | #B16 | Reserve | - | - |
| #B40 | #B17 | Signal cable inner antenna in the passenger compartment (rear) (-) | f=125kHz U=300Vpp The signal is difficult to measure. |
Only the V50. Located under the carpet in the luggage compartment. Only active when searching for remote keys. Otherwise 0 V. |
| #B41 | #B18 | Not connected | - | - |
| #B42 | #B19 | Not connected | - | - |
| #B43 | #B20 | Not connected | - | - |
| #B44 | #B21 | Not connected | - | - |
| #B45 | #B22 | Not connected | - | - |
| #B46 | #B23 | Not connected | - | - |
Connector C
| Connector C | ||||
|---|---|---|---|---|
| Breakout box terminal | Control module terminal | Signal type | Active / Not active | Miscellaneous |
| #B1 | #C1 | Power supply, quick lock right-hand rear (-) | Ulow | Not C30 and C70. |
| #B2 | #C2 | Power supply, quick lock left-hand rear (-) | Ulow | Not C30 and C70. |
| #B3 | #C3 | Reserve | - | - |
| #B4 | #C4 | Ground terminal | Ulow | - |
| #B5 | #C5 | Power supply | Ubat | - |
| #B6 | #C6 | Not connected | - | |
| #B7 | #C7 | Not connected | - | |
| #B8 | #C8 | Not connected | - | |
| #B9 | #C9 | Not connected | - | |
| #B10 | #C10 | Not connected | - | |
| #B11 | #C11 | Not connected | - | |
| #B12 | #C12 | Not connected | - | |
| #B13 | #C13 | Not connected | - | |
| #B14 | #C14 | Not connected | - | |
| #B15 | #C15 | Not connected | - | |
| #B16 | #C16 | Not connected | - | |
| #B17 | #C17 | Not connected | - | |
| #B18 | #C18 | Reserve | - | |
| #B19 | #C19 | Not connected | - | |
| #B20 | #C20 | Not connected | - | |
| #B21 | #C21 | Reserve | - | |
| #B22 | #C22 | Not connected | - | |
| #B23 | #C23 | Reserve | - | |
Connector D
| Connector D | ||||
|---|---|---|---|---|
| Breakout box terminal | Control module terminal | Signal type | Active / Not active | Miscellaneous |
| #A24 | #D1 | Power supply quick lock left front. | > 10.5 V / < 1.5 V | Active when opening doors |
| #A25 | #D2 | Power supply quick lock right front. | > 10.5 V / < 1.5 V | Active when opening doors. |
| #A26 | #D3 | LS-CAN H | 2.5-4 V The signal is difficult to measure. |
During communication. |
| #A27 | #D4 | LS-CAN L | 2.5-1 V The signal is difficult to measure. |
During communication. |
| #A28 | #D5 | Reserve | - | |
| #A29 | #D6 | Not connected | - | |
| #A30 | #D7 | Not connected | - | |
| #A31 | #D8 | Reserve | - | - |
| #A32 | #D9 | Contact breaker in quick lock left front | Ulow | Open circuit, Grounded when the handle is pulled out to its limit position |
| #A33 | #D10 | Reserve | - | - |
| #A34 | #D11 | Reserve | - | - |
| #A35 | #D12 | Reserve | - | - |
| #A36 | #D13 | Reserve | - | - |
| #A37 | #D14 | Signal cable Remote Keyless Entry (RKE) | 0.5 V / 1.5 V | Serial communication. Signals are difficult to read. |
| #A38 | #D15 | Indication of remote control in the starter module (Key In) | - | Signal from the central electronic module (CEM) when remote key is inserted in the starter module. |
| #A39 | #D16 | Reserve | - | - |
| #A40 | #D17 | Reserve | - | - |
| #A41 | #D18 | Reserve | - | |
| #A42 | #D19 | Reserve | - | |
| #A43 | #D20 | Reserve | - | - |
| #A44 | #D21 | Switch quick lock right rear | f=125kHz U=300Vpp (106 Vrms ) The signal is difficult to measure. |
When fault-tracing the key. Reading taken against corresponding (-) terminal 0 V not active. Not C30 and C70. |
| #A45 | #D22 | Switch quick lock right front | Ulow | Open circuit, Grounded when the handle is pulled out to its limit position |
| #A46 | #D23 | Reserve | - | - |
Connector E
| Connector E | ||||
|---|---|---|---|---|
| Breakout box terminal | Control module terminal | Signal type | Active / Not active | Miscellaneous |
| #A1 | #E1 | Reserve | - | - |
| #A2 | #E2 | Outer lock button right front | Ulow | Open circuit. Indicates ground connection when button is depressed. |
| #A3 | #E3 | Contact breaker at clutch pedal | Ulow | Closes when the clutch pedal is depressed to 75% of length of stroke. |
| #A4 | #E4 | Switch unlocking left rear | Ulow | Open circuit. Indicates ground connection when pulling out the external door handle. Not C30 and C70. |
| #A5 | #E5 | Outer lock button right rear | Ulow | Open circuit. Indicates ground connection when button is depressed. Not C30 and C70. |
| #A6 | #E6 | Not connected | - | |
| #A7 | #E7 | Not connected | - | |
| #A8 | #E8 | Not connected | - | |
| #A9 | #E9 | Not connected | - | |
| #A10 | #E10 | Not connected | - | |
| #A11 | #E11 | Not connected | - | |
| #A12 | #E12 | Not connected | - | |
| #A13 | #E13 | Not connected | - | |
| #A14 | #E14 | Contact breaker at brake pedal. | 0 V / 5V | Signal from the central electronic module (CEM) when brake pedal is depressed. |
| #A15 | #E15 | Switch quick lock left rear | Ulow | Open circuit. Grounded when the handle is pulled out to its limit position. Not C30 and C70. |
| #A16 | #E16 | Reserve | - | - |
| #A17 | #E17 | External lock button left rear | Ulow | Open circuit. Indicates ground connection when button is depressed. Not C30 and C70. |
| #A18 | #E18 | Switch unlocking luggage compartment lid | Ulow | Open circuit. Indicates ground connection when pulling out the external door handle. |
| #A19 | #E19 | Outer lock button left front | Ulow | Open circuit. Indicates ground connection when button is depressed. |
| #A20 | #E20 | Switch unlocking right rear. | Ulow | Open circuit. Indicates ground connection when pulling out the external door handle. Not C30 and C70. |
| #A21 | #E21 | Switch unlocking left front. | Ulow | Open circuit. Indicates ground connection when pulling out the external door handle. |
| #A22 | #E22 | Switch unlocking right front. | Ulow | Open circuit. Indicates ground connection when pulling out the external door handle. |