Signal Specification
All values listed below should be measured between the respective connection in column 1 (control module connection) and connection B1 (#A5).
CONNECTOR A
| Control module terminal | Breakout box terminal | Signal type | In / Out | Pump to left | Pump to right | Miscellaneous |
| #A1 | A1 | Hydraulic pump, power supply | Out | U = Ubat | U=Ulow | Itype =25 A (Imax =60 A, 200 ms) |
| #A2 | A2 | Hydraulic pump, ground | Out | U=Ulow | U = Ubat | Itype =25 A (Imax =60 A, 200ms) |
CONNECTOR B
| Control module terminal | Breakout box terminal | Signal type | In / Out | Ignition on | Miscellaneous |
| #B1 | A5 | Ground to Convertible Roof Module (CRM) for hydraulic pump | In | U=Ulow | Itype =25 A (Imax =60 A, 200 ms) |
| #B2 | A6 | 30 supply to Convertible Roof Module (CRM) for hydraulic pump | In | U = Ubat | Itype =25 A (Imax =60 A, 200 ms) |
| #B3 | A7 | Ground to Convertible Roof Module (CRM)/valves/electric catches | In | U=Ulow | Itype =9 A (Imax =27 A, 400 ms) |
| #B4 | A8 | 30 supply to Convertible Roof Module (CRM)/valves/electric catches | In | U = Ubat | Itype =9 A (Imax =27 A, 400 ms) |
CONNECTOR C
| Control module terminal | Breakout box terminal | Signal type | In / Out | On | Off | Miscellaneous |
| #C1 | A11 | Temperature sensor, hydraulic pump (-) | In | - | - | Imin =3 mA |
| #C2 | A12 | Hydraulic valve 1, power supply (+) | Out | U = Ubat | U=Ulow | Imax =2 A |
| #C3 | A13 | Hydraulic valve 2, power supply (+) | Out | U = Ubat | U=Ulow | Imax =2 A |
| #C4 | A14 | Hydraulic valve 3, power supply (+) | Out | U = Ubat | U=Ulow | Imax =2 A |
| #C5 | A15 | Hydraulic valve 4, power supply (+) | Out | U = Ubat | U=Ulow | Imax =2 A |
| #C6 | A16 | - | - | - | - | - |
| #C7 | A17 | Temperature sensor, hydraulic pump (+) | In | - | - | Imin =3 mA |
| #C8 | A18 | Hydraulic valve 1, ground (-) | Out | U=Ulow | U=Ulow | Imax =2 A |
| #C9 | A19 | Hydraulic valve 2, ground (-) | Out | U=Ulow | U=Ulow | Imax =2 A |
| #C10 | A20 | Hydraulic valve 3, ground (-) | Out | U=Ulow | U=Ulow | Imax =2 A |
| #C11 | A21 | Hydraulic valve 4, ground (-) | Out | U=Ulow | U=Ulow | Imax =2 A |
| #C12 | A22 | - | - | - | - | - |
CONNECTOR D
| Control module terminal | Breakout box terminal | Signal type | In / Out | On | Off | Miscellaneous |
| #D1 | A31 | Electric catch motor, ground (-) | Out | - | - | Itype =7 A (Imax =25 A, 400 ms) |
| #D2 | A32 | Lockable storage compartment, motor (-) | Out | - | - | - |
| #D3 | A33 | Hall sensor, electric catch motor (+) | In | U=9 V | U=0.7 V | Pulsating Imax =20 mA |
| #D4 | A34 | Hall sensor, electric catch motor (-) | Out | U=Ulow | U=Ulow | Imax =28 mA |
| #D5 | A35 | Position sensor 2, rear roof section, ground (-) | Out | U=Ulow | U=Ulow | Imax =27 mA |
| #D6 | A36 | Position sensor 17, front roof section, signal | In | U=0.50-4.5 V | U=0.50-4.5 V | Varying voltage depending on roof position. Imax =11 mA |
| #D7 | A37 | Position sensor 17, front roof section, supply voltage (+5 V) | Out | U =5 V | U=Ulow | Imax =16 mA |
| #D8 | A38 | Spare | - | - | - | - |
| #D9 | A39 | Spare | - | - | - | - |
| #D10 | A40 | Spare | - | - | - | - |
| #D11 | A41 | Hall sensor 12 | In | U=0.51-1.275 V | U=3.06-4.335 V | Imax =17 mA |
| #D12 | A42 | Electric catch motor, power supply (+) | Out | - | - | Itype =7 A (Imax =25 A, 400 ms) |
| #D13 | A43 | Lockable storage compartment, motor (+) | Out | - | - | USA/CANADA:
Lockable storage compartments discontinued from and incl. structure week 200946. OTHER MARKETS: Lockable storage compartments discontinued from and incl. structure week 201020. |
| #D14 | A44 | - | - | - | - | - |
| #D15 | A45 | Spare | - | - | - | - |
| #D16 | A46 | Position sensor 17, front roof section, ground (-) | Out | U=Ulow | U=Ulow | Imax =27 mA |
| #D17 | A47 | Position sensor 2, rear roof section, signal | In | U=0.5-4.5 V | U=0.5-4.5 V | Varying voltage depending on roof position. Imax =11 mA |
| #D18 | A48 | Position sensor 2, rear roof section, supply voltage (+5 V) | Out | U =5 V | U=Ulow | Imax =16 mA |
| #D19 | A49 | Spare | - | - | - | - |
| #D20 | A50 | Spare | - | - | - | - |
| #D21 | A51 | Hall sensor, power supply (+) | Out | U = Ubat | U=Ulow | Imax =8 mA |
| #D22 | A52 | Hall sensor 13 | In | U=0.51-1.275 V | U=3.06-4.335 V | Imax =17 mA |
CONNECTOR E
| Control module terminal | Breakout box terminal | Signal type | In / Out | Active | Passive | Miscellaneous |
| #E1 | B1 | Hall sensor 9 | In | U=0.51-1.275 V | U=3.06-4.335 V | Imin
=2 mA Imax =17 mA |
| #E2 | B2 | Hall sensor 19 | In | U=0.51-1.275 V | U=3.06-4.335 V | Imin
=2 mA Imax =17 mA |
| #E3 | B3 | Hall sensor 11 | In | U=0.51-1.275 V | U=3.06-4.335 V | Imin
=2 mA Imax =17 mA |
| #E4 | B4 | Hall sensor 18 | In | U=0.51-1.275 V | U=3.06-4.335 V | Imin
=2 mA Imax =17 mA |
| #E5 | B5 | Hall sensor 15 | In | U=0.51-1.275 V | U=3.06-4.335 V | Imin
=2 mA Imax =17 mA |
| #E6 | B6 | Hall sensor 16 | In | U=0.51-1.275 V | U=3.06-4.335 V | Imin
=2 mA Imax =17 mA |
| #E7 | B7 | Hall sensor 6 | In | U=0.51-1.275 V | U=3.06-4.335 V | Imin
=2 mA Imax =17 mA |
| #E8 | B8 | Hall sensor 3 | In | U=0.51-1.275 V | U=3.06-4.335 V | Imin
=2 mA Imax =17 mA |
| #E9 | B9 | Hall sensor 7 | In | U=0.51-1.275 V | U=3.06-4.335 V | Imin
=2 mA Imax =17 mA |
| #E10 | B10 | Spare | ||||
| #E11 | B11 | Spare | |
|||
| #E12 | B12 | Spare | ||||
| #E13 | B13 | Hall sensor, power supply (+), HS6, HS18 | Out | U = Ubat | U=Ulow | With ignition off U=0V. Itot =91 mA |
| #E14 | B14 | Hall sensor, power supply (+), HS15, HS16, HS19 | Out | U = Ubat | U=Ulow | With ignition off U=0V. Itot =209 mA |
| #E15 | B15 | Hall sensor, power supply (+), HS3, HS7, HS9, HS11, 12, HS13 | Out | U = Ubat | U=Ulow | With ignition off U=0V. Itot =209 mA |
| #E16 | B16 | Spare |
CONNECTOR F
| Control module terminal | Breakout box terminal | Signal type | In / Out | On | Off | Miscellaneous |
| #F1 | B21 | CAN H | In / Out | |||
| #F2 | B22 | Spare | ||||
| #F3 | B23 | Control, roof closure | In | U=Ulow | U = Ubat | Itype
=15 mA Imax =20 mA |
| #F4 | B24 | Spare (sensor 19) | ||||
| #F5 | B25 | Hall sensor 10 | In | U=0.51-1.275 V | U=3.06-4.335 V | Imin
=2 mA Imax =17 mA |
| #F6 | B26 | Hall sensor 5 | In | U=0.51-1.275 V | U=3.06-4.335 V | Imin
=2 mA Imax =17 mA |
| #F7 | B27 | Spare | ||||
| #F8 | B28 | Spare | In / Out | |||
| #F9 | B29 | CAN L | In / Out | |||
| #F10 | B30 | Control, load aid system | In | U=Ulow | U = Ubat | Itype
=15 mA Imax =20 mA |
| #F11 | B31 | Control, roof opening | In | U=Ulow | U = Ubat | Itype
=15 mA Imax =20 mA |
| #F12 | B32 | Spare (sensor 18) | ||||
| #F13 | B33 | Hall sensor, power supply (+), HS1, HS5, HS10 | Out | U = Ubat | U=Ulow | Itot =91 mA |
| #F14 | B34 | Hall sensor 1 | In | U=0.51-1.275 V | U=3.06-4.335 V | Imin
=2 mA Imax =17 mA |
| #F15 | B35 | Spare | ||||
| #F16 | B36 | Spare |