Checking The Power Supply And Ground Terminal
- Ignition off.
Check the cable between central electronic module (CEM) #H6 (#20) and Remote Receiver Module (RRX) #A1 for open circuit.
Check the signal cable between central electronic module (CEM) #H3 (#17) and Remote Receiver Module (RRX) #A2 for open circuit, short-circuit to ground, and short-circuit to voltage.
Check the cable between Remote Receiver Module (RRX) #A3 and ground for open circuit. Also check the ground connection for oxidation.
Remedy the cables as necessary.
Other information
Was a fault detected?
- YES
Refer to VERIFICATION
- NO
Refer to CHECKING COMMUNICATION