Signal Specification

WARNING: This page does not describe the selected car, but rather 12 other vehicles, including the 2014 Volvo XC90, 2013 Volvo XC90, 2012 Volvo XC90, 2011 Volvo XC90, and 2010 Volvo XC90. However, it is still accessible from the selected car via links, so may be relevant.

All values given below are between the respective terminal in column 1 and terminal #3 (power ground) unless otherwise stated in brackets after the entry. Control module terminals #1-#16 correspond to terminals #1-#16 on the breakout box.

NOTE: It is important to connect the breakout box and check the ground terminals before taking readings.
U= DC voltage in volts (V) UAC = AC voltage in volts (V)
Ubat = Battery voltage (V) f = Frequency in Hertz (Hz)
Ulow = Voltage approximately 0 V % duty = Duty cycle (pulse ratio) as a percentage (%)
t = Time in milliseconds (ms) - -
Terminal  Signal type  Ignition on  Engine idling  Other 
#1 Glow plug signal Glow plug off: U=Ulow
Glow plug on: Pulse ratio (% duty) > 0%
Pulse ratio (% duty) increases with glow plug intensity.
#2 - - -
#3 Power ground
(Measured to the battery negative terminal)
U low -
#4 Signal ground, engine coolant temperature sensor and flame sensor U low -
#5 - - -
#6 Communication cable for the central electrical module (CEM) - Digital signal -
#7 - - - -
#8 Flame sensor signal Flame not lit: U≈5 V
Flame lit: U<1.5 V
-
#9 30-supply (Power supply from battery) U bat -
#10 Combustion fan control signal Combustion fan off and power supply off: U low
Combustion fan off and power supply on: U bat
Fan on: Pulse ratio (% duty) > 0%
The pulse ratio (% duty) increases with fan speed.
#11
Model year -2001
Power supply, combustion fan, fuel pump (FP) and water pump Power supply off: U low
Power supply on: U bat
-
#11
Model year 2002-
Power supply, combustion fan and water pump Power supply off: U low
Power supply on: U bat
-
#12 Water pump control signal Water pump off and power supply off: U low
Water pump off and power supply on: U bat
Water pump on and power supply on: U low
-
#13 Fuel pump control signal Fuel pump off: f=0 Hz
Fuel pump on: f>0 Hz
The frequency increases with pump speed
#14 - - -
#15 Extended X-supply U bat U bat -
#16 Coolant temperature sensor signal +20°C: U ≈ 3.5 V
+75°C= 2.02 V
+90°C= 0.78 V
The voltage decreases with increasing temperature