RECIRCULATION Control (Electronic Climate Control Only)

WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2013 Volvo C70, 2012 Volvo C70, 2011 Volvo C70, 2010 Volvo C70, and 2009 Volvo C70. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Identifying Climate Control Module (CCM)
GLL140261Courtesy of VOLVO CARS CORPORATION

For ECC, the climate control module (CCM) (3/112) controls the recirculation during the following conditions:

The air quality sensor (AQS) (7/159) transmits a signal to the climate control module (CCM) if it detects raised concentrations of pollutants in the outside air. When this occurs, the climate control module (CCM) transmits a signal to the damper motor for recirculation (6/48) to close the fresh air damper and to use recirculated air.

The degree of recirculation is controlled by the signal from the air quality sensor (AQS):

If the high level of pollutants remains the system stays in recirculation for certain time, maximum of 10 minutes. The time that the system is recirculating is determined by the outside temperature, if air conditioning (A/C) is on or the windshield wipers are activated. The system returns to fresh air for a short time before recirculation is resumed. The particle filter absorbs most of the pollutant entering the passenger compartment during this time. The maximum time prevents misting and musty air.

The air quality sensor (AQS) transmits information about the content of pollutants to the climate control module (CCM). This information is graded into four levels, and the information used for diagnosis.

Recirculation is never permitted if defroster is selected. The climate control module (CCM) (for ECC) also requests compressor activation when the evaporator temperature exceeds 3 °C.