LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Volvo >> 2016 >> S80 T5 >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Drivers Assistance Systems - ADAS >> Electrical Equipment - Specifications, Other >> Vehicle Communication, Forward Sensing Module (FSM) >> Vehicle Communication, Forward Sensing Module (FSM), New Design With Camera [2008-2012] >> Description Of Parameters
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Description Of Parameters

PARAMETERS, VALUE 

POWER SUPPLY, FSM 

Indicates the power supply to the forward sensing module (FSM).

Measurement range: 6 to 20 V.

The normal value when the alternator is charging: 13.0-14.5 V.

AUTOMATIC SETTING 

Shows offset value for forward sensing radar. The offset value is generated due to mechanical distortion. Forward sensing radar manages to compensate for a horizontal distortion of up to 2.5 degrees, seen from straight ahead.

Measurement range: - 12.8 till + 12.7 degrees.

Normal value: approximately 0.0 degrees.

VOLTAGE SUPPLY, FORWARD LOOKING CAMERA 

Shows the voltage supply to the forward looking camera.

Measuring range: 0 - 20 V.

Normal value: approx. 4.2 - 4.6 V.