Diagnostic Mode 6: Checking test results of components that are not continuously monitored: Notes
This diagnostic mode displays the test results of emission relevant components and systems which are not continuously monitored.
The values of the individual test results must reach the specified value or must be within the min.- and max.- limits.
Test requirements
- Exhaust system must be properly sealed between the catalytic converter and the cylinder heads → Exhaust system, checking for proper seal .
- No DTCs in the DTC memory. → Diagnostic Mode 3: Interrogating DTC memory .
- Coolant temperature at least 80° C.
Work procedure
- Connect diagnostic tester. → Diagnostic tester, connecting .
- Start engine and let run at idle speed.
- In diagnostic function "address word 33 - OBD" select "Mode 6: Check test results of components that are not continuously monitored".
Select desired "Test-ID", e.g. "Test-ID 01: Oxygen Sensor Monitor Bank 1 - Sensor 1", via the following table.
The current minimum and maximum values will be displayed on the diagnostic tester screen.