Test 18B - Repairing Disarm Sense Circuit From Remote Keyless Entry Module
NOTE:
For connector terminal identification, refer to CONNECTOR IDENTIFICATION
. For wiring diagrams, see WIRING DIAGRAM
.
NOTE:
Perform TEST 18A
before proceeding with TEST 18B.
- Ensure all courtesy, dome and cargo lights are functioning properly. Repair interior lights as necessary. If lights are functioning properly, go to next step.
- Turn ignition off. Disconnect Remote Keyless Entry (RKE) module. See Figure in TEST 3A. Using DRB in voltmeter mode, check voltage at RKE module connector terminal No. 7 (Violet/Yellow wire). If voltage is less than 10 volts, repair open in courtesy light control circuit (Dark Blue/Orange wire). Perform TEST VER-1 . If voltage is more than 10 volts, replace RKE module. Perform TEST VER-1 .