Programming The RFH
If a Body Control Module (BCM) is also going to be replaced at this time, check the "RF-HUB, BCM, FOBIK REPLACEMENT AND PROGRAMMING ORDER GUIDE" before proceeding. Refer to STANDARD PROCEDURE .
Do not put a laptop or any wireless device (cell phones, audio devices etc.) near the top of the center console (the RKE antenna is located below the center console).
- After the RFH has been replaced with new unit, connect the diagnostic scan tool to the Data Link Connector (DLC).
- Navigate to the RFH in the "Vehicle View" of the diagnostic scan tool.
- With the scan tool select "RFH" and perform the "RF-HUB Replace" routine.NOTE:
This procedure will require you to log into DealerCONNECT and enter a PIN when requested. The PIN is temporary and will be active for 12 hours. After 12 hours, a new PIN will need to be obtained from DealerCONNECT.
- Select "Misc. Function" and perform the "PROXI Configuration Alignment" routine.
- Put all the FOBiKs used in this vehicle on the front seat away from the console.
- With the scan tool select: "Program ignition FOBIKs" in the Miscellaneous Functions menu and follow the instructions on the screen.NOTE:
When programming a FOBIK, have it in your hand resting on the console.
NOTE:When you are instructed to "Press the Unlock button" it is important that you do not hold the button. Press it One time quickly.
NOTE:This procedure will require you to log into DealerCONNECT and enter a PIN when requested. The PIN is temporary and will be active for 12 hours. After 12 hours, a new PIN will need to be obtained from DealerCONNECT.
- After all the FOBIKs have been programmed, turn the ignition on and with the scan tool select "BCM".
- Update the Front and Rear Axle Normal Tire Pressure Values.
- Program the Tire Sensor IDs.
- Turn the ignition to the OFF position, wait 30 seconds, then cycle the ignition back to the ON/RUN position.
- Check for any active RFH DTCs. If any are present, perform the appropriate procedure. Refer to DIAGNOSTIC CODE INDEX, RFH
- Turn the ignition off and check each FOBiK for proper operation.
- Finish the installation procedure (if necessary). Refer to MODULE, RADIO FREQUENCY (RF HUB), INSTALLATION .
- Perform the BODY VERIFICATION TEST. Refer to BODY VERIFICATION TEST .