Automatic air conditioning system component summary, location/task/design/function - GF83.40-P-9990Q
WARNING: This page is about a different variant/trim than selected.
MODEL 209.3 /4 except CODE (581) Comfort automatic air conditioning
| Front SAM control unit with fuse and relay module, location/task/design | GF54.21-P-4108Q | ||
| Rear SAM control unit with fuse and relay module, location/task | Model 209.3 | GF54.21-P-4130Q | |
| Model 209.4 | GF54.21-P-4130QA | ||
| Left door control unit, location/task | GF72.29-P-4122Q | ||
| Right door control unit, location/task | GF72.29-P-4123Q | ||
| Rear door control unit, location/purpose | Model 209.3 | GF54.21-P-4133Q | |
| Power soft top control unit, location/task/ design/function | Model 209.4 | GF77.37-P-3200QA | |
| Electronic ignition switch control unit, location/task | GF80.57-P-4120Q | ||
| Overhead control panel control unit, location/ task/design | Model 209.3 | GF82.20-P-4110Q | |
| Model 209.4 | GF82.20-P-4110QA | ||
| Blower motor location/task/design/function | GF83.10-P-2170Q | ||
| Blower regulator, location/task/function | GF83.10-P-2141Q | ||
| Air ducting, location/task/function | GF83.10-P-2182Q | ||
| Combination filter, location/task/design/ function | Model 209.3 with engine 612, 642, 646 up to 31.5.07 Model 209.4 with engine 642 up to 31.5.07 Model 209.3/4 as of 1.6.07 |
GF83.10-P-2128Q | |
| Dust filter, location/task/function | With engine 112, 113, 271, 272, 273, 156 up to 31.5.07 | GF83.10-P-2142P | |
| Heating system heat exchanger, location/ task/function | GF83.20-P-2108P | ||
| Heater water circulation pump, location/task/ function | With code (670) Residual engine heat utilization system (REST [MRA]) | GF83.20-P-2109P | |
| Air humidity sensor, location/task/design/ function | up to 28.6.06 | GF83.30-P-2125Q | |
| Control and operating unit for automatic air conditioning, location/task | Model 209.3 | GF83.40-P-2180Q | |
| Model 209.4 | GF83.40-P-2180QA | ||
| Actuator motors for automatic air conditioning, location/task/function | GF83.40-P-2182Q | ||
| Air conditioner housing, location/task/design/ function | GF83.40-P-2105Q | ||
| Engine and AC electric suction fan with integrated control location/task/function | GF83.40-P-2172Q | ||
| Condenser location/task/function | GF83.40-P-2152Q | ||
| Evaporator location/task/design/function | GF83.40-P-2121P | ||
| Fluid reservoir location/task/design/function | GF83.40-P-2122Q | ||
| Expansion valve, location/task/design/ function | GF83.40-P-2123P | ||
| Coolant temperature sensor location/task/ function | GF83.40-P-2184Q | ||
| Refrigerant pressure and temperature sensor location/task/function | GF83.40-P-2171Q | ||
| Refrigerant compressor, location/task/design/ function | GF83.55-P-2100P | ||
| Refrigerant compressor control valve location/ task/function | GF83.55-P-2102P | ||
| Belt pulley, location/task/design/function | GF83.55-P-2103P | ||
| Pressure relief valve location/task/function | GF83.55-P-2104P | ||
| Evaporator core temperature sensor, location/ task/function | GF83.57-P-2109P | ||
| Outside temperature indicator temperature sensor location/task/function | GF83.57-P-2119Q | ||
| Heater booster control unit, location/task/ design | Model 209.3 with engine 612 or 646 | GF83.70-P-4059Q | |
| Table of contents, automatic air conditioning (AAC) function description | GF83.40-P-0999Q |