Check Hazard Light Operation

Step Check Yes No
1 CHECK HAZARD LIGHT OPERATION  .
Make sure the hazard light blinks when hazard switch is turned to ON.
Does the hazard light blink? Go to step . Check the hazard light circuit.
2 CHECK BODY INTEGRATED UNIT SETTING  .
Display the data of «Abnormal warning lamp flashing setting» using Subaru Select Monitor.
NOTE: For detailed operation procedures, refer to "Application help".
Is the setting ON? Go to step . Turn the setting to ON.
3 CHECK DATA MONITOR  .
Display the data of «Hazard Output» using Subaru Select Monitor.
Is output signal present when operating the transmitter LOCK/UNLOCK button? Go to step . Go to step .
4 CHECK KEYLESS ENTRY OPERATION  .
Press the LOCK/UNLOCK button of the keyless transmitter.
Does it operate properly? Replace the body integrated unit. <Ref. to BODY INTEGRATED UNIT .> Check keyless entry system. <Ref. to SYMPTOM CHART , INSPECTION, Keyless Entry System.>
5 CHECK HAZARD LIGHT CIRCUIT. 
  1. Disconnect the connectors of the body integrated unit and turn signal & hazard unit.
  2. Check the harness between body integrated unit and turn signal & hazard unit.

    Connector & terminal 

    (i171) No. 18 - (B32) No. 8: 

Is harness normal? Check body integrated unit. <Ref. to Basic Diagnostic Procedure .> Repair or replace the harness.