Check Room Light Operation
| Step | Check | Yes | No |
|---|---|---|---|
| 1 CHECK ROOM LIGHT OPERATION
. Make sure the room light illuminates when the room light switch is ON, and goes off when the switch is OFF. |
Does the room light illuminate or go off? | Go to step 2 . | Check the room light circuit. <Ref. to INSPECTION , Room Light.> |
2 CHECK ROOM LIGHT OPERATION
.
|
Does the room light illuminate ← → go off (including off delay) when the door is opened and closed? | Go to step 3 . | Go to step 4 . |
| 3 CHECK KEYLESS ENTRY OPERATION
. Press the LOCK/UNLOCK button of the keyless transmitter. |
Does it operate properly? | Room light is normal. | Check keyless entry system. <Ref. to SYMPTOM CHART , INSPECTION, Keyless Entry System.> |
| 4 CHECK ROOM LIGHT
. Check the room light. <Ref. to INSPECTION , Room Light.> |
Is room light normal? | Go to step 5 . | Replace the bulb or room light assembly. |
5 CHECK HARNESS
.
|
Is harness normal? | Go to step 6 . | Repair or replace the harness. |
| 6 CHECK HARNESS
. Measure the voltage between the room light connector and chassis ground. Connector & terminal (R52) No. 3 (+) - Chassis ground (-): |
Is the voltage 10 V or more? | Replace the body integrated unit. <Ref. to BODY INTEGRATED UNIT .> | Repair or replace the harness. |